Cinq facteurs à prendre en compte lors de l’achat d’une chambre d’essai environnementale

Cinq facteurs à prendre en compte lors de l’achat d’une chambre d’essai environnementale



Environmental test chambers, also known as temperature and humidity environment chamber, climate chamber, is commonly used in laboratories and factories for environmental simulation systems and devices. Environmental test chamber can simulate temperature, humidity, air pressure, light, vibration, corrosion and other different environmental conditions. The test chamber is usually composed of control system, heating system, refrigeration system, humidity control system, air pressure control system, lighting system, vibration system, corrosion system and so on. According to the test requirements, different environmental parameters can be selected for adjustment to simulate the required environmental conditions. There are many kinds of environment boxes. For people who are not familiar with environment boxes and who buy them for the first time, choosing environment boxes is a very headache. Therefore, through this article, I will help you to understand how to choose the right temperature and humidity environment room? In addition, if you want to know more about the standards and applications of temperature and humidity boxes, you can contact our company's technical staff. We will give you a satisfactory answer as soon as possible.

1. Exigences relatives aux essais

Tout d’abord, il est nécessaire de définir le type de produit, les paramètres de test et les normes de test pour sélectionner la chambre d’essai environnementale qui répond aux exigences du test. Il est important d’analyser en détail vos exigences d’essai lors du choix de la chambre d’essai environnementale adaptée à vos besoins. Considérez d’abord le type d’environnement que vous testez et s’il présente des conditions extrêmes, telles que la température, l’humidité ou l’altitude. Deuxièmement, pour considérer votre secteur d’activité, tel que : Industrie des produits électroniques et électriques : Les produits électroniques et électriques doivent subir des tests à basse température, à haute température, à haute température, à haute et à basse température, à brouillard salin, à chaleur et à humidité, vibrations, chutes et autres, afin d’évaluer leur fiabilité et leur durabilité dans différents environnements.

2. Sélection de la plage de température

La plage de la chambre d’essai de température étrangère est généralement de -73 ~ + 177 °C ou -70 ~ 180 °C. Les fabricants nationaux de produits sont principalement -80 ~ + 130 °C, -60 ~ + 130 °C, -40 ~ + 130 °C, haute température à 150 °C. Ces plages de température répondent généralement aux besoins de la plupart des tests de température militaires et civils.

3. Plage d’humidité

Select the appropriate humidity range according to the test requirements. Some test chambers can simulate very high humidity (such as 95%RH or higher), while others are suitable for very dry environments (such as 0%RH) where the higher the temperature, the lower the relative humidity for the same absolute moisture content. For example, the absolute moisture content is 5g/kg, and when the temperature is 29℃, the relative humidity is 20%RH. When the temperature is 6°C, the relative humidity is 90% RH. When the temperature drops below 4℃ and the relative humidity exceeds 100%, condensation will occur in the box. The temperature index of environmental test chamber at home and abroad is generally 20~98%RH or 30~98%RH. If the constant temperature and humidity box does not have a dehumidification system, the temperature ranges from 60 to 98%. The chamber can only be used for high humidity tests, but it is much cheaper. It is important to note that the humidity indicator should be followed by the corresponding temperature range or minimum dew point temperature. Because relative humidity is directly related to temperature.

4. Précision du contrôle

The control precision of environmental test chamber has important influence on the accuracy and reliability of test results. The appropriate control precision needs to be selected according to the test requirements. Usually, the more accurate the control, the higher the price of the equipment. The relative humidity deviation of environmental test chamber should be ±2%RH or ±3%RH. In order to meet the requirements of temperature control accuracy, the temperature fluctuation is generally less than ±0.2℃; otherwise, it is difficult to meet the requirements of humidity control accuracy

5. Vitesse du vent

Selon les normes en vigueur, lors de la réalisation de tests environnementaux, la vitesse du vent dans la boîte de test de température et d’humidité doit être inférieure à 1,7 m/s. Mais si la nécessité d’une chambre d’essai à changement rapide de température et la température, l’humidité, les vibrations et d’autres facteurs d’une chambre d’essai environnementale complète, accélérez le débit d’air en circulation dans le réservoir. La vitesse du vent est généralement de 2 ~ 3 m / s. Pour la plupart des exigences d’essai générales, la vitesse du vent dans la chambre d’essai environnemental est généralement comprise entre 0,5 m/s et 2,5 m/s, et la vitesse du vent dans cette plage peut répondre à la plupart des exigences d’essai. Par exemple, pour le test des produits électroniques et électriques, la plage de vitesse du vent courante est de 0,5 m/s à 1,5 m/s ; Pour les essais de pièces automobiles, une plage de vitesse du vent courante est de 1,5 m/s à 2,5 m/s.

Contactez-nous